openTherm to M-Bus Monitor

Product details
Manufacturer: ista Nederland B.V.
Brand: ista Nederland B.V.
Product identification: openTherm to M-Bus Monitor
Product description:

Monitor openTherm communication and output all received details on M-Bus line.

Company
Company name: ista Nederland B.V.
City: Schiedam
Country: NETHERLANDS
Interfaces
Interface 1 (Master)
Interface 2 (Slave)
Functions and Features
general: info
general: service/diagnostics
ch: info
ch: service/diagnostics
dhw: service/diagnostics
dhw: info
cooling: service/diagnostics
cooling: info
solar: service/diagnostics
solar: info
ventilation: info
ventilation: service/diagnostics
ID's
ID0:HB0: Master status: CH enable
ID0:HB1: Master status: DHW enable
ID0:HB2: Master status: Cooling enable
ID0:HB3: Master status: OTC active
ID0:HB4: Master status: CH2 enable
ID0:HB5: Master status: Summer/winter mode
ID0:HB6: Master status: DHW blocking
ID0:LB0: Slave Status: Fault indication
ID0:LB1: Slave Status: CH mode
ID0:LB2: Slave Status: DHW mode
ID0:LB3: Slave Status: Flame status
ID0:LB4: Slave Status: Cooling status
ID0:LB5: Slave Status: CH2 mode
ID0:LB6: Slave Status: Diagnostic/service indication
ID0:LB7: Slave Status: Electricity production
ID1: Control Setpoint i.e. CH water temperature Setpoint (°C)
ID2:HB0: Master configuration: Smart power
ID2:LB: Master MemberID Code
ID3:HB0: Slave configuration: DHW present
ID3:HB1: Slave configuration: Control type
ID3:HB2: Slave configuration: Cooling configuration
ID3:HB3: Slave configuration: DHW configuration
ID3:HB4: Slave configuration: Master low-off&pump control
ID3:HB5: Slave configuration: CH2 present
ID3:HB6: Slave configuration: Remote water filling function
ID3:HB7: Heat/cool mode control
ID3:LB: Slave MemberID Code
ID4 (HB=1): Remote Request Boiler Lockout-reset
ID4 (HB=2): Remote Request Water filling
ID4 (HB=10): Remote Request Service request reset
ID5:HB0: Service request
ID5:HB1: Lockout-reset
ID5:HB2: Low water pressure
ID5:HB3: Gas/flame fault
ID5:HB4: Air pressure fault
ID5:HB5: Water over-temperature
ID5:LB: OEM fault code
ID6:HB0: Remote boiler parameter transfer-enable: DHW setpoint
ID6:HB1: Remote boiler parameter transfer-enable: max. CH setpoint
ID6:LB0: Remote boiler parameter read/write: DHW setpoint
ID6:LB1: Remote boiler parameter read/write: max. CH setpoint
ID7: Cooling control signal (%)
ID8: Control Setpoint for 2e CH circuit (°C)
ID9: Remote override room Setpoint
ID10: Number of Transparent-Slave-Parameters supported by slave
ID11: Index number / Value of referred-to transparent slave parameter
ID12: Size of Fault-History-Buffer supported by slave
ID13: Index number / Value of referred-to fault-history buffer entry
ID14: Maximum relative modulation level setting (%)
ID15: Maximum boiler capacity (kW) / Minimum boiler modulation level(%)
ID16: Room Setpoint (°C)
ID17: Relative Modulation Level (%)
ID18: Water pressure in CH circuit (bar)
ID19: Water flow rate in DHW circuit. (litres/minute)
ID20: Day of Week and Time of Day
ID21: Calendar date
ID22: Calendar year
ID23: Room Setpoint for 2nd CH circuit (°C)
ID24: Room temperature (°C)
ID25: Boiler flow water temperature (°C)
ID26: DHW temperature (°C)
ID27: Outside temperature (°C)
ID28: Return water temperature (°C)
ID29: Solar storage temperature (°C)
ID30: Solar collector temperature (°C)
ID31: Flow water temperature CH2 circuit (°C)
ID32: Domestic hot water temperature 2 (°C)
ID33: Boiler exhaust temperature (°C)
ID34: Boiler heat exchanger temperature (°C)
ID35: Boiler fan speed Setpoint and actual value
ID36: Electrical current through burner flame [µA]
ID37: Room temperature for 2nd CH circuit (°C)
ID38: Relative Humidity
ID48: DHW Setpoint upper & lower bounds for adjustment (°C)
ID49: Max CH water Setpoint upper & lower bounds for adjustment (°C)
ID56: DHW Setpoint (°C) (Remote parameter 1)
ID57: Max CH water Setpoint (°C) (Remote parameters 2)
ID70:HB0: Master status ventilation / heat-recovery: Ventilation enable
ID70:HB1: Master status ventilation / heat-recovery: Bypass postion
ID70:HB2: Master status ventilation / heat-recovery: Bypass mode
ID70:HB3: Master status ventilation / heat-recovery: Free ventilation mode
ID70:LB0: Slave status ventilation / heat-recovery: Fault indication
ID70:LB1: Slave status ventilation / heat-recovery: Ventilation mode
ID70:LB2: Slave status ventilation / heat-recovery: Bypass status
ID70:LB3: Slave status ventilation / heat-recovery: Bypass automatic status
ID70:LB4: Slave status ventilation / heat-recovery: Free ventilation status
ID70:LB6: Slave status ventilation / heat-recovery: Diagnostic indication
ID71: Relative ventilation position (0-100%). 0% is the minimum set ventilation and 100% is the maximum set ventilation
ID72: Application-specific fault flags and OEM fault code ventilation / heat-recovery
ID73: An OEM-specific diagnostic/service code for ventilation / heat-recovery system
ID74:HB0: Slave Configuration ventilation / heat-recovery: System type
ID74:HB1: Slave Configuration ventilation / heat-recovery: Bypass
ID74:HB2: Slave Configuration ventilation / heat-recovery: Speed control
ID74:LB: Slave MemberID Code ventilation / heat-recovery
ID75: The implemented version of the OpenTherm Protocol Specification in the ventilation / heat-recovery system
ID76: Ventilation / heat-recovery product version number and type
ID77: Relative ventilation (0-100%)
ID78: Relative humidity exhaust air (0-100%)
ID79: CO2 level exhaust air (0-2000 ppm)
ID80: Supply inlet temperature (°C)
ID81: Supply outlet temperature (°C)
ID82: mExhaust inlet temperature (°C)
ID83: Exhaust outlet temperature (°C)
ID84: Exhaust fan speed in rpm
ID85: Supply fan speed in rpm
ID86:HB0: Remote ventilation / heat-recovery parameter transfer-enable: Nominal ventilation value
ID86:LB0: Remote ventilation / heat-recovery parameter read/write : Nominal ventilation value
ID87: Nominal relative value for ventilation (0-100 %)
ID88: Number of Transparent-Slave-Parameters supported by TSP’s ventilation / heat-recovery
ID89: Index number / Value of referred-to transparent TSP’s ventilation / heat-recovery parameter
ID90"Size of Fault-History-Buffer supported by ventilation / heat-recovery
ID91: Index number / Value of referred-to fault-history buffer entry ventilation / heat-recovery
ID98: For a specific RF sensor the RF strength and battery level is written
ID99: perating Mode HC1, HC2/ Operating Mode DHW
ID100: Function of manual and program changes in master and remote room Setpoint
ID101:HB012: Master Solar Storage: Solar mode
ID101:LB0: Slave Solar Storage: Fault indication
ID101:LB123: Slave Solar Storage: Solar mode status
ID101:LB45: Slave Solar Storage: Solar status
ID102: Application-specific fault flags and OEM fault code Solar Storage
ID103:HB0: Slave Configuration Solar Storage: System type
ID103:LB: Slave MemberID Code Solar Storage
ID104: Solar Storage product version number and type
ID105: Number of Transparent-Slave-Parameters supported by TSP’s Solar Storage
ID106: Index number / Value of referred-to transparent TSP’s Solar Storage parameter
ID107: Size of Fault-History-Buffer supported by Solar Storage
ID108: Index number / Value of referred-to fault-history buffer entry Solar Stor
ID109: Electricity producer starts
ID110: Electricity producer hours
ID111: Electricity production
ID112: Cumulativ Electricity production
ID113: Number of un-successful burner starts
ID114: Number of times flame signal was too low
ID115: OEM-specific diagnostic/service code
ID116: Number of succesful starts burner
ID117: Number of starts CH pump
ID118: Number of starts DHW pump/valve
ID119: Number of starts burner during DHW mode
ID120: Number of hours that burner is in operation (i.e. flame on)
ID121: Number of hours that CH pump has been running
ID122: Number of hours that DHW pump has been running or DHW valve has been opened
ID123: Number of hours that burner is in operation during DHW mode
ID124: The implemented version of the OpenTherm Protocol Specification in the master
ID125: The implemented version of the OpenTherm Protocol Specification in the slave
ID126: Master product version number and type
ID127: Slave product version number and type