Draadloze OpenTherm Module

Product details
Manufacturer: Honeywell B.V.
Brand: Honeywell B.V.
Product identification: R8810A1018v4
Product description:

Is een ketelmodule voor aansturing van een met OpenTherm modulerende cv-toestel

Company
Company name: Honeywell B.V.
City: AMSTERDAM ZUIDOOST
Country: NETHERLANDS
Interfaces
Interface 1 (Master)
Functions and Features
ch: max setpoint adjustment
ch: otc control
ch: remote lockout-reset
ch: remote parameters
ch: remote room setpoint
ch: roomtemp control
ch: service/diagnostics
dhw: setpoint adjustment
general: standard
ID's
ID0:HB0: Master status: CH enable
ID0:HB1: Master status: DHW enable
ID0:HB2: Master status: Cooling enable
ID0:HB3: Master status: OTC active
ID0:HB5: Master status: Summer/winter mode
ID0:HB6: Master status: DHW blocking
ID0:LB0: Slave Status: Fault indication
ID0:LB1: Slave Status: CH mode
ID0:LB2: Slave Status: DHW mode
ID0:LB3: Slave Status: Flame status
ID1: Control Setpoint i.e. CH water temperature Setpoint (°C)
ID10: Number of Transparent-Slave-Parameters supported by slave
ID12: Size of Fault-History-Buffer supported by slave
ID126: Master product version number and type
ID127: Slave product version number and type
ID14: Maximum relative modulation level setting (%)
ID16: Room Setpoint (°C)
ID17: Relative Modulation Level (%)
ID18: Water pressure in CH circuit (bar)
ID19: Water flow rate in DHW circuit. (litres/minute)
ID2:HB0: Master configuration: Smart power
ID2:LB: Master MemberID Code
ID24: Room temperature (°C)
ID25: Boiler flow water temperature (°C)
ID26: DHW temperature (°C)
ID27: Outside temperature (°C)
ID28: Return water temperature (°C)
ID3:HB0: Slave configuration: DHW present
ID3:HB1: Slave configuration: Control type
ID3:HB4: Slave configuration: Master low-off&pump control
ID48: DHW Setpoint upper & lower bounds for adjustment (°C)
ID49: Max CH water Setpoint upper & lower bounds for adjustment (°C)
ID5:HB0: Service request
ID5:HB1: Lockout-reset
ID5:HB2: Low water pressure
ID5:HB3: Gas/flame fault
ID5:HB4: Air pressure fault
ID5:HB5: Water over-temperature
ID5:LB: OEM fault code
ID56: DHW Setpoint (°C) (Remote parameter 1)
ID57: Max CH water Setpoint (°C) (Remote parameters 2)
ID6:HB0: Remote boiler parameter transfer-enable: DHW setpoint
ID6:HB1: Remote boiler parameter transfer-enable: max. CH setpoint
ID6:LB0: Remote boiler parameter read/write: DHW setpoint
ID6:LB1: Remote boiler parameter read/write: max. CH setpoint
ID9: Remote override room Setpoint