Smart HubSwitch

Product details
Manufacturer: Bury sp. z o.o.
Brand: Wunda Group PLC
Product identification: Smart HubSwitch
Product description:

The HubSwitch is the brains of WundaSmart. It manages all your commands and communicates them with every part of the system.
The HubSwitch has up to 4 configurable channels, which makes it the perfect universal option for any heating system.

Company
Company name: Wunda Group PLC
City: Caldicot
Country: UNITED KINGDOM
Interfaces
Interface 1 (Master)
Functions and Features
ch: max setpoint adjustment
ch: roomtemp control
dhw: setpoint adjustment
general: standard
ID's
ID0:HB0: Master status: CH enable
ID0:HB1: Master status: DHW enable
ID0:HB5: Master status: Summer/winter mode
ID0:LB0: Slave Status: Fault indication
ID0:LB1: Slave Status: CH mode
ID0:LB2: Slave Status: DHW mode
ID0:LB3: Slave Status: Flame status
ID0:LB6: Slave Status: Diagnostic/service indication
ID1: Control Setpoint i.e. CH water temperature Setpoint (°C)
ID14: Maximum relative modulation level setting (%)
ID15: Maximum boiler capacity (kW) / Minimum boiler modulation level(%)
ID17: Relative Modulation Level (%)
ID18: Water pressure in CH circuit (bar)
ID19: Water flow rate in DHW circuit. (litres/minute)
ID25: Boiler flow water temperature (°C)
ID26: DHW temperature (°C)
ID27: Outside temperature (°C)
ID3:HB0: Slave configuration: DHW present
ID3:HB1: Slave configuration: Control type
ID3:HB2: Slave configuration: Cooling configuration
ID3:HB3: Slave configuration: DHW configuration
ID3:HB4: Slave configuration: Master low-off&pump control
ID3:HB5: Slave configuration: CH2 present
ID3:HB6: Slave configuration: Remote water filling function
ID3:HB7: Heat/cool mode control
ID3:LB: Slave MemberID Code
ID48: DHW Setpoint upper & lower bounds for adjustment (°C)
ID49: Max CH water Setpoint upper & lower bounds for adjustment (°C)
ID5:HB0: Service request
ID5:HB1: Lockout-reset
ID5:HB2: Low water pressure
ID5:HB3: Gas/flame fault
ID5:HB4: Air pressure fault
ID5:HB5: Water over-temperature
ID5:LB: OEM fault code
ID56: DHW Setpoint (°C) (Remote parameter 1)
ID57: Max CH water Setpoint (°C) (Remote parameters 2)
ID6:HB0: Remote boiler parameter transfer-enable: DHW setpoint
ID6:HB1: Remote boiler parameter transfer-enable: max. CH setpoint
ID6:LB0: Remote boiler parameter read/write: DHW setpoint
ID6:LB1: Remote boiler parameter read/write: max. CH setpoint